Null


Bowl-snoot gasket

  • 3 Replies
  • 1056 Views

bahner80

  • Join Date: Nov 2015
  • Location: Menifee
  • *
  • Sr. Member
  • ****
  • Posts: 419
  • Karma: +15/-0
  • Registered User
    • View Profile
  • Liked:
  • Likes Given: 0
« on: September 05, 2017, 03:37:32 PM »
So I got about 6 hours on the pump .
Dominator 12s suction housing /inducer
Berkeley bowl and droop
Place diverter.
Motor and pump are both fresh ,been taking it easy this summer and both haven't seen wot throttle (its been hard)
Noticed this gasket rearing it's head last run out @ parker.
Oh it's got an A impeller,
Curious if anyone has had this problem  before


Null


bahner80

  • Join Date: Nov 2015
  • Location: Menifee
  • *
  • Sr. Member
  • ****
  • Posts: 419
  • Karma: +15/-0
  • Registered User
    • View Profile
  • Liked:
  • Likes Given: 0
« Reply #1 on: September 07, 2017, 10:00:34 AM »
Anyone?

fullfam1

  • Join Date: May 2013
  • Location: Sacramento
  • *
  • Jr. Member
  • **
  • Posts: 88
  • Karma: +1/-0
  • Registered User
    • View Profile
  • Liked:
  • Likes Given: 2
« Reply #2 on: September 07, 2017, 01:03:55 PM »
Had same issue bolts were slightly loose so it pushed gasket out. Make sure surfaces clean and flat then replace gasket and tighten. Re tighten after running it a couple of hours


Sent from my iPhone using SoCal Jet Boats

bahner80

  • Join Date: Nov 2015
  • Location: Menifee
  • *
  • Sr. Member
  • ****
  • Posts: 419
  • Karma: +15/-0
  • Registered User
    • View Profile
  • Liked:
  • Likes Given: 0
« Reply #3 on: September 07, 2017, 01:16:53 PM »
Already checked all bolts. That was my first thought and we're all tight gonna replace gasket tonight.thinking maybe bolts are a lil too long .
We'll  see when I pull it apart.good time to grease the bearing also.