SoCal Jet Boats

Tech Talk => Engine Mechanical / Electrical => Topic started by: Tio Pancho on August 19, 2011, 07:02:18 PM

Title: Log & Snail Question
Post by: Tio Pancho on August 19, 2011, 07:02:18 PM
On the bottom of the snails there are 2 ports. The one closest to the front is where they were originally plumbed. Is there any reason we cannot use the rear port?  We are having a clearance issues with one side, and since the snails rise slightly as they go back I believe that it would clear if we plumbed them there?

Thanks
Title: Re: Log & Snail Question
Post by: Nixonnow on August 19, 2011, 07:05:26 PM
edit-  whoops....nevermind. i didnt read it very well. sorry.
Title: Re: Log & Snail Question
Post by: Your Mom on August 19, 2011, 09:20:50 PM
Open it up and see if the water will flow the same direction.  You want the water to run its full length of the snail keeping it cool.
Title: Re: Log & Snail Question
Post by: Tio Pancho on August 20, 2011, 11:15:29 AM
Trying to do that now. Can't get the plug out of the back port.  :mad: Trying not to strip or break anything.
Title: Re: Log & Snail Question
Post by: Your Mom on August 20, 2011, 11:58:29 AM
Had to have a set welded up as removing the fitting took a small piece of the thread with it... no big deal. Finding another set of snails is easy...
Title: Re: Log & Snail Question
Post by: obnoxious001 on August 20, 2011, 10:21:58 PM
Trying to do that now. Can't get the plug out of the back port.  :mad: Trying not to strip or break anything.

Heating the aluminum around the plug with a propane torch will many times make it easy to remove a stuck plug.