Flared fittings into NPT threads?
« on: February 20, 2009, 06:02:36 AM »
I want to run S/S tubing for my water lines, I have the bender and some tube so why not? Can I just flare the tubing and use a flare nut to install it into the NPT threads on my water plates and t-stat housing?
Thanks
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
"Don't you realize that there are already enough people in the world to hate without you putting so much effort into giving me another?"

GT Jets

  • Karma: +192/-0
Re: Flared fittings into NPT threads?
« Reply #1 on: February 20, 2009, 05:35:29 PM »
I want to run S/S tubing for my water lines, I have the bender and some tube so why not? Can I just flare the tubing and use a flare nut to install it into the NPT threads on my water plates and t-stat housing?
Thanks

Just so you know, AN and flare are different, the angle on the face is where the difference is, the threads are the same, I have used copper tubing before on a closed cooling system for a fishing boat, worked killer and once they were painted engine color looked factory...

In assume you're going to just use a MPT to flare adapter, I say sure why not, just remember to put in an expansion bend for vibration...

GT
« Last Edit: February 20, 2009, 05:40:28 PM by GT Jets »
  • Boat #1: 1992 Carrera 20.5 Elite (I/O bitches)
  • Boat #2: 19' Bubble deck Jet BBC Berkeley
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
If i get some free time tonight at work, ill play with it and post it for everyone to see.

Time to man up and yank it John!  :banghead:
Ray

SLCKREG

  • Karma: +0/-0
Re: Flared fittings into NPT threads?
« Reply #2 on: February 20, 2009, 06:12:21 PM »
I've thought of hardlines a time or 2 , I was thinking he would still need a npt to an adapter, and the hard lines got flaired to 37*(which is different than say brake lines). I'm all ears on this one because I'm not sure. Re the flair/an deal, a week or 2 ago I ordered a -08 to npt adapter from jegs #100129 and it says ,flair to pipe adapter 45 degree -08 to 1/2" npt. Just curious why they would label it both flair and an?? I think other than bending lines, the only trick is getting the right flairing tool for the lines. But wtf do I know,lol
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

Donjuan

  • Karma: +0/-0
Re: Flared fittings into NPT threads?
« Reply #3 on: February 22, 2009, 02:54:20 PM »
I stopped by Jet Boat Performance yesterday and talked to Tom about the water lines and how they are built. Just curious how you were going to get them to collect into one. What you were going to use to sodder them together in the larger tube with. He was saying that you have to use silver sodder. Talked jto a jeweler friend who said it is stronger than lead  sodder plus it has a higher melting temp which is good since it is going to be next to direct heat.
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
Up with hope and down with dope. I am all about hugs not drugs.

SLCKREG

  • Karma: +0/-0
Re: Flared fittings into NPT threads?
« Reply #4 on: February 22, 2009, 03:48:42 PM »
What would you need to solder? Just because he's going to run hard lines doesn't mean he can't use t-fittings ect??
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

GT Jets

  • Karma: +192/-0
Re: Flared fittings into NPT threads?
« Reply #5 on: February 22, 2009, 03:54:18 PM »
What would you need to solder? Just because he's going to run hard lines doesn't mean he can't use t-fittings ect??

I think Donjuan is confusing water lines with the header feed lines... :sly:

GT
  • Boat #1: 1992 Carrera 20.5 Elite (I/O bitches)
  • Boat #2: 19' Bubble deck Jet BBC Berkeley
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
If i get some free time tonight at work, ill play with it and post it for everyone to see.

Time to man up and yank it John!  :banghead:
Ray

Donjuan

  • Karma: +0/-0
Re: Flared fittings into NPT threads?
« Reply #6 on: February 22, 2009, 08:27:34 PM »
My bad. I was thinking the water injection lines to the headers. Newb mistake.
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
Up with hope and down with dope. I am all about hugs not drugs.

 


Null

SMFPacks CMS 1.0.3 © 2026