Null


just squirtin

  • Karma: +1/-0
Re: Hydraulic Place Diverter Lines
« Reply #25 on: February 10, 2008, 10:25:04 AM »
hey gaw=you are in sacramento=im in rio linda=you could come over and take a look see at set up on my boat if you like=my number is 212-4964=give a buzz if interested
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

GAWnCA

  • Karma: +1/-1
Re: Hydraulic Place Diverter Lines
« Reply #26 on: February 10, 2008, 10:36:55 AM »
hey gaw=you are in sacramento=im in rio linda=you could come over and take a look see at set up on my boat if you like=my number is 212-4964=give a buzz if interested

Maybe one day this week we can hook up.  Thanks!
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
~Greg
Forgive your enemies.  It messes up their heads.

76NORDIC

  • Karma: +23/-0
Re: Hydraulic Place Diverter Lines
« Reply #27 on: February 10, 2008, 12:06:08 PM »
I had a problem with my pump bouncing out of the plastic bracket when i hit rough water. What i did was, put a piece of innertube between the transom and the hyd pump tightened the screws and it has not bounced out since (2yrs) Last summer one fo my Park Moabi trips had some storrmy weatheron the way back from needles was one hell of a test thot i was on the ocean and it didnt budge   Mark
  • Boat #1: 76 Nordic BBF 460 Jet
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
The definition of insanity: Doing the same thing over and over again, and expecting different results.....Einstein

I refuse to call people an ass anymore. It insults hard working donkeys worldwide!

GAWnCA

  • Karma: +1/-1
Re: Hydraulic Place Diverter Lines
« Reply #28 on: February 10, 2008, 12:46:05 PM »
I had a problem with my pump bouncing out of the plastic bracket when i hit rough water. What i did was, put a piece of innertube between the transom and the hyd pump tightened the screws and it has not bounced out since (2yrs) Last summer one fo my Park Moabi trips had some storrmy weatheron the way back from needles was one hell of a test thot i was on the ocean and it didnt budge   Mark

Now, if I can find a inner tube.  ??? Thanks for the tip, I'll try it!
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
~Greg
Forgive your enemies.  It messes up their heads.

beerjet

  • Karma: +81/-0
Re: Hydraulic Place Diverter Lines
« Reply #29 on: February 10, 2008, 01:06:44 PM »
Mine stopped workin once (cuz it was upside down) and have yet to figure out a way to bolt it back down .

-beerjet-
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
i dont but im all for stuffin shit in her ass to make her go away :-*

GAWnCA

  • Karma: +1/-1
Re: Hydraulic Place Diverter Lines
« Reply #30 on: February 10, 2008, 01:30:15 PM »
Mine stopped workin once (cuz it was upside down) and have yet to figure out a way to bolt it back down .

-beerjet-

How did your pump get up side down?  I'm mounting mine to the transom since the hydraulic lines come in through the transom housing.  I am wondering if I should put a wedge in between the pump and the transom since there is some degree of slant.  I was also thinking about drilling some over sized holes, epoxy in some hard wood dowels for the mounting screws to bite into rather than the old plywood.  The plywood doesn't look all that bad, just would rather have something a little more solid.

Here's a thought, thread the hard wood dowel and tap the hole then epoxy it in place.  Should add even more gripping power.
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
~Greg
Forgive your enemies.  It messes up their heads.

76NORDIC

  • Karma: +23/-0
Re: Hydraulic Place Diverter Lines
« Reply #31 on: February 10, 2008, 02:25:19 PM »
Jus my .02 but the rubber trick i did was real simple, and its like the rubber takes alot of the shock and takes the slip factor away. Another  thing i should prolly mention is it wasnt inner tube but a type of rubber from where i work, very similar to an inneer tube but thicker. Pm me and i can send ya a piece if ya want one. Mark
  • Boat #1: 76 Nordic BBF 460 Jet
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
The definition of insanity: Doing the same thing over and over again, and expecting different results.....Einstein

I refuse to call people an ass anymore. It insults hard working donkeys worldwide!

RTriebess

  • Karma: +0/-0
Re: Hydraulic Place Diverter Lines
« Reply #32 on: February 10, 2008, 02:59:43 PM »
we bought a box with a cover and bolted it to the stringers and the cover had a strap to hold down

never had any problems with movement
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

GAWnCA

  • Karma: +1/-1
Re: Hydraulic Place Diverter Lines
« Reply #33 on: February 10, 2008, 04:07:06 PM »
Jus my .02 but the rubber trick i did was real simple, and its like the rubber takes alot of the shock and takes the slip factor away. Another  thing i should prolly mention is it wasnt inner tube but a type of rubber from where i work, very similar to an inneer tube but thicker. Pm me and i can send ya a piece if ya want one. Mark

I might be able to come up with a piece of mud flap and if it works great, if not, I'll PM you.  Thanks for the offer.  Greg
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
~Greg
Forgive your enemies.  It messes up their heads.

just squirtin

  • Karma: +1/-0
Re: Hydraulic Place Diverter Lines
« Reply #34 on: February 10, 2008, 05:52:05 PM »
that would be fine greg=mondays/tuesdays=home by 5 pm   wed/fri i  have high school bbgames gone all nite
thursday anytime after 2:30pm =give me a ring===doug
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

GAWnCA

  • Karma: +1/-1
Re: Hydraulic Place Diverter Lines
« Reply #35 on: February 10, 2008, 06:12:45 PM »
Well, I mounted the pump to the inside fo the transom and now need to figure out how to connect those plastic lines to the pump. You can see the lines going up over the back.  The pump connections are on this end of the pump just below the solenoids.  Any one have any suggestions?

  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
~Greg
Forgive your enemies.  It messes up their heads.

just squirtin

  • Karma: +1/-0
Re: Hydraulic Place Diverter Lines
« Reply #36 on: February 10, 2008, 08:34:52 PM »
with all the pounding you are going to have the way you mounted the pump will probaby pull the screws out because of not being supported in the front=as i suggested on previous post -bulkhead fittings will work well and you donot need to caulk around them and they are a solid mount against the transom=i have had ours for three years with no leaks and no moving around problems

plus an enclosed box box might be better as you donot have to worry about water getting into any connections or such and makes a cleaner looking installation
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

GAWnCA

  • Karma: +1/-1
Re: Hydraulic Place Diverter Lines
« Reply #37 on: February 11, 2008, 06:00:05 AM »
Hey Doug,  Have you got a photo of how you installed your pump?  Where did you find a small box to put it in?   Greg
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
~Greg
Forgive your enemies.  It messes up their heads.

just squirtin

  • Karma: +1/-0
Re: Hydraulic Place Diverter Lines
« Reply #38 on: February 11, 2008, 11:32:47 AM »
geoff i am not quite photo savy to post but i will give it a shot tonight=how far away do you live from sac
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

just squirtin

  • Karma: +1/-0
Re: Hydraulic Place Diverter Lines
« Reply #39 on: February 11, 2008, 05:37:31 PM »
het gaw=i tried to email you some photos=it replied that 5 photos were sent=let me know if they are the right ones
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

just squirtin

  • Karma: +1/-0
Re: Hydraulic Place Diverter Lines
« Reply #40 on: February 14, 2008, 09:40:49 PM »
hey greg was wondering if you got the photos i emailed you on the diverter pump and hose set up
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

GAWnCA

  • Karma: +1/-1
Re: Hydraulic Place Diverter Lines
« Reply #41 on: February 14, 2008, 09:42:44 PM »
hey greg was wondering if you got the photos i emailed you on the diverter pump and hose set up

I haven't seen it but then Comcast has been doing some really goofy things lately.  Check your PM.
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party
~Greg
Forgive your enemies.  It messes up their heads.

just squirtin

  • Karma: +1/-0
Re: Hydraulic Place Diverter Lines
« Reply #42 on: February 21, 2008, 06:40:41 PM »
this is the box with pump inside=its bolted to the stringer
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

just squirtin

  • Karma: +1/-0
Re: Hydraulic Place Diverter Lines
« Reply #43 on: February 21, 2008, 06:42:35 PM »
i have the lines going thru transom thru bulkhead fittings
  • Like
    Dislike
    Love
    HaHa
    Angry
    Surprise
    Sad
    Party

 


Null

SMFPacks CMS 1.0.3 © 2026